Geekzone: technology news, blogs, forums
Guest
Welcome Guest.
You haven't logged in yet. If you don't have an account you can register now.
Compass Communications pioneers EcoCooling in New Zealand
Posted on 1-Jun-2015 11:14 | Tags Filed under: News


Compass Communications pioneers EcoCooling in New Zealand
Telecommunications provider Compass Communications has introduced EcoCooling at its new Te Rapa data centre facility. With the difficulty of maintaining the operating temperatures of powerful computers among the major challenges facing data centre operators, EcoCooling is up to 90% more efficient than traditional air conditioning systems, reducing power consumption and delivering a more environmentally friendly facility. Best of all, it does that using nothing but air and water and has no moving parts.

Compass Communications CNS Operations Manager Steve McCarthy, says this has been proven in over 200 data centres around the world. “Traditional data centre cooling uses lots of chilled water which in turn uses a lot of power. EcoCooling, on the other hand, uses filtered fresh air and tap water. Now, for the first time, EcoCooling is being put to work in New Zealand, resulting in a data centre which costs less to run.”

Produced by a United Kingdom-based company, the EcoCooling system leverages the principle of evaporative cooling; when water evaporates, heat is absorbed and the temperature drops (a principle which is at work to cool us when we sweat). The EcoCooling system draws in fresh air, filters it and measures the temperature; if it is too cool, the incoming air is mixed with exhaust air from the data centre. Too warm, and the air is cooled through the evaporation of water, which is supplied into the system at normal mains pressures. Air of the appropriate temperature is then circulated into the servers and other equipment within the data centre.

“A cold air containment system is in place, with ducting above, feeding cool air into the front of the equipment. Hot air is extracted and vented, or reused in the system if required,” McCarthy adds.

He points out that the traditional perception that data centre equipment requires cold air has given way to an understanding that continuous flow is what is required. “If that air is between 23 and 26 degrees, with controlled humidity, it is quite suitable.”

With electricity high among the costs of any data centre, the new Compass facility enjoys advantages unique in New Zealand thanks to the application of EcoCooling technology, which McCarthy says reduces operating costs by up to 25%, offsetting to some extent the considerable capital investment involved in establishing a new data centre.

The Compass Communications Te Rapa facility is in the process of being commissioned and is Compass Communication’s second data centre. Designed as a Disaster Recovery site, it complements the company’s existing Auckland site or any other hosting site for high availability configurations.






comments powered by Disqus


Trending now »

Hot discussions in our forums right now:

Auckland Airport fuel supply obliterated by digger
Created by Batman, last reply by k1wi on 23-Sep-2017 03:12 (220 replies)
Pages... 13 14 15


iPhone 8/iPhone X, impressions?
Created by surfisup1000, last reply by Krishant007 on 26-Sep-2017 07:19 (431 replies)
Pages... 27 28 29


Driving an automatic - do you use one foot or both?
Created by geekIT, last reply by Aredwood on 25-Sep-2017 22:48 (143 replies)
Pages... 8 9 10


Car pulling left - even after alignment
Created by Paul1977, last reply by Coil on 26-Sep-2017 13:06 (40 replies)
Pages... 2 3


vodafone shutting down email?
Created by FatFurryGuy, last reply by Rickles on 26-Sep-2017 13:04 (299 replies)
Pages... 18 19 20


Could a production electric car reach 500 KPH anytime soon?
Created by kingdragonfly, last reply by Coil on 26-Sep-2017 13:09 (24 replies)
Pages... 2


Spam Text
Created by rendezvous, last reply by hio77 on 25-Sep-2017 22:00 (24 replies)
Pages... 2


Changing ISP due to Vodafone email closing down
Created by Gradine, last reply by 1101 on 25-Sep-2017 09:39 (34 replies)
Pages... 2 3